c. Clean the Compressor. Remove any accumulation of dust and dirt from the
compressor periodically.
(1)
Check the intake silencer for heavy accumulation of dust or dirt.
(2)
Replace the intake silencer if there is a heavy accumulation of dust or
dirt.
WARNING
Do not use any type of liquid cleaner or solvent to clean the intake
silencer element.
CAUTION:
Do not restrict air flow through the air intake silencer.
d. Inspect the Running/Starting Capacitors. Ensure there is no corrosion on
the terminals or any indication of a chemical leak from the capacitors.
e. Verify the Compressor. The final step of PMCS is to verify the compressor
is operating to manufacturer's specification. Refer to Lesson 2, Perform Verification of
Compressor.
MD0366
1-12