Figure 4-1. Dryer and cooling coil assembly.
b. Remove the Dryer and Cooling Coil Assembly. To remove the dryer and
cooling coil assembly, refer to figure 4-1 and use the following procedures.
(1)
Disconnect the cable from the cooling fan to the circuit breaker at the
connector.
(2)
Disconnect the fittings between:
(a) The top of the drying chamber and the metal flex hose to the flow
control valve.
(b) The cooling coil and metal flex hose to the unloader valve.
(3) Remove two nuts, lock washers, and flat washers from the bolts
securing the dryer and cooling assembly to the compressor assembly base plate.
(4)
Replace the malfunctioning component.
(5)
Reassemble unit in the reverse order of removal.
(6)
Ensure that all fittings are leak proof.
(7) Apply a paste-type pipe dope to all threads, except compression fittings,
before assembling.
MD0366
4-3